Factory Price Rexroth A2fe Series Hydraulic Motor A2fe28 A2fe32 A2fe45 A2fe56

Factory Price Rexroth A2fe Series Hydraulic Motor A2fe28 A2fe32 A2fe45 A2fe56

Factory cost CZPT A2FE series hydraulic motor A2FE28 A2FE32 A2FE45 A2FE56

Brueninghaus Hydromatik CZPT A2FE motor
 
CZPT fastened motor A2FE28, A2FE32, A2FE45, A2FE56, A2FE63, A2FE80, A2FE90, A2FE107, A2FE125, A2FE160, A2FE180,
A2FE250, A2FE355

Description  

Open up and shut circuits
Sequence 61 and 60
Force:
Measurement 28 to180 Nominal strain 5800 psi (four hundred bar)/ Peak stress 6500 psi (450 bar)
Size 250 to 355 Nominal strain 5100 psi (350 bar)/ Peak force 5800 psi (four hundred bar)
 
The A2FE set plug-in motor with axial tapered piston rotary group of bent-axis design, for hydrostatic drives in open up and shut circuits
-Considerably-reaching integration in mechanical gearbox due to recessed mounting flange situated in the center of the circumstance (very area-preserving development)
-The output speed is dependent on the flow of the pump and the displacement of the motor.
-The output torque will increase with the stress differential among the large-force and the reduced-stress side.
-Tiny dimensions.
-Large overall performance.
-Comprehensive device, prepared-assembled and tested.
-Easy to install, simply plug into the mechanical gearbox.
-No configuration technical specs to be noticed when putting in.
 
Technical Data 
Table of values (theoretical values, with out performance and tolerances values rounded)

CZPT A2FE motor A2FE28 A2FE32 A2FE45 A2FE56 A2FE63 A2FE80  
Displacement Vg cm3 28.one 32 45.six fifty six.1 sixty three eighty.four  
Pace highest nnom rpm 6300 6300 5600 5000 5000 4500  
nmax2) rpm 6900 6900 6200 5500 5500 5000  
Enter stream Vg qV L/min 177 202 255 281 315 362  
Torque at Vg and Dp = 350 bar T Nm 157 178 254 313 351  
Dp = four hundred bar T Nm 179 204 290 357 401  
Rotary stiffness c kNm/ rad 2.ninety three 3.twelve four.18 five.94 six.25 eight.73  
Minute of inertia JGR  kgm2 .0012 .0012 .0571 .0042 .0042 .0072  
Highest angular a rad/s2 6500 6500 14600 7500 7500 6000  
Case quantity V  L .2 .two .33 .45 .forty five .55  
Mass (approx.) m kg 10.5 ten.five 15 eighteen 19 23  
Size A2FE90 A2FE107 A2FE125 A2FE160 A2FE180 A2FE250 A2FE355
Displacement Vg cm3 ninety 106.7 a hundred twenty five 160.4 a hundred and eighty 250 355
Speed highest nnom rpm 4500 4000 4000 3600 3600 2700 2240
nmax2) rpm 5000 4400 4400 4000 4000
Input stream qV L/min 405 427 500 577 648 675 795
Torque at Vg Dp = 350 bar T 501 594 696 893 1003 1393 1978
Dp = four hundred bar T 573 679 796 1571 1146
Rotary stiffness c kNm/rad 9.fourteen 11.two 11.9 17.4 eighteen.2 seventy three.one ninety six.1
Instant of inertia JGR kgm2 .0072 .0116 .0116 .571 .571 .061 .102
Maximum angular a rad/s2 6000 4500 4500 3500 3500 10000 8300
Situation volume V L .fifty five .eight .eight one.1 1.one two.5 three.5
Mass (approx.) m kg 25 34 36 forty seven forty eight 82 a hundred and ten

CZPT fluid
Ahead of starting undertaking plHangCZPT, make sure you refer to our info sheets RE 95710 (mineral oil), RE 95711 (environmentally acceptable hydraulic fluids) and RE 95712 (HFD hydraulic fluids) and RE 95713 (HFA, HFB, HFC hydraulic fluids) for thorough data relating to the choice of hydraulic fluid and application problems. The plug-in motor A2FE is not appropriate for procedure with HFA hydraulic fluid. If HFB, HFC or HFD or environmentally acceptable hydraulic fluids are employed, the restrictions with regards to technological info or other seals must be observed.
Information relating to the decision of hydraulic fluid
The right choice of hydraulic fluid demands understanding of the functioning temperature in relation to the ambient temperature: in a shut circuit, the circuit temperature, in an open circuit, the reservoir temperature. The hydraulic fluid should be selected so that the operating viscosity in the working temperature variety is inside of the the best possible variety (νopt), see shaded spot of the variety diagram. We advisable that the greater viscosity course be picked in every scenario. Example: At an ambient temperature of X °C, an functioning temperature of 60 °C is set in the circuit. In the ideal operating viscosity selection (νopt., shaded area) this corresponds to the viscosity courses VG forty six or VG 68 to be chosen: VG sixty eight.
Observe: The situation drain temperature, which is influenced by force and velocity, can be greater than the circuit temperature or reservoir temperature. At no point of the component may the temperature be greater than 115 °C. The temperature big difference specified underneath is to be taken into account when deciding the viscosity in the bearing. If the above conditions can’t be taken care of due to excessive working parameters, we advocate the use of a flushing and boost strain valve.
Shaft seal
Permissible strain loading the provider lifestyle of the shaft seal is motivated by the pace of the axial piston unit and the case drain pressure (scenario strain). The suggest differential pressure of two bar among the situation and the ambient pressure could not be enduringly exceeded at typical operating temperature. For a increased differential force at lowered speed, see diagram. Momentary strain spikes (t < 0.1 s) of up to 10 bar are permitted. The service life of the shaft seal decreases with an increase in the frequency of pressure spikes.

 

Factory Price Rexroth A2fe Series Hydraulic Motor A2fe28 A2fe32 A2fe45 A2fe56